Уточнить поиск
Результаты 1-5 из 5
The poisons around us
1974
Schroeder, Henry Alfred
Biosorption of Multifold Toxic Heavy Metal Ions from Aqueous Water onto Food Residue Eggshell Membrane Functionalized with Ammonium Thioglycolate Полный текст
2013
Wang, Sha | Wei, Minghong | Huang, Yuming
A new biosorbent material from eggshell membrane was synthesized through thiol functionalization, which is based on the reduction of disulfide bonds in eggshell membrane by ammonium thioglycolate. The thiol-functionalized eggshell membrane was characterized, and its application as an adsorbent for removal of Cr(VI), Hg(II), Cu(II), Pb(II), Cd(II), and Ag(I) from aqueous water has been investigated. The experimental results revealed that the adsorption abilities of the thiol-functionalized eggshell membrane toward Cr(VI), Hg(II), Cu(II), Pb(II), Cd(II), and Ag(I) improved 1.6-, 5.5-, 7.7-, 12.4-, 12.7-, and 21.1-fold, respectively, compared with that of the eggshell membrane control. The adsorption mechanism and adsorption performance, including the adsorption capacity and the kinetics of the thiol-functionalized eggshell membrane for the target heavy metals, were investigated. The effects of solution pH, coexisting substances, and natural water matrices were studied. The thiol-functionalized eggshell membrane can be used as column packing to fabricate a column for real wastewater purification.
Показать больше [+] Меньше [-]A new coprecipitation method without carrier element for separation and preconcentration of some metal ions at trace levels in water and food samples Полный текст
2016
Gouda, Ayman A.
A new simple and sensitive preconcentration, separation and environmentally friendly method based on carrier element free coprecipitation (CEFC) was developed using 4-(2-hydroxybenzylideneamino)-1,2-dihydro-2,3-dimethyl-1-phenylpyrazol-5-one (APSAL) as a new organic co-precipitant to precipitate Cr³⁺, Cu²⁺, Fe³⁺, Pb²⁺ and Zn²⁺ ions from water and food samples. The levels of the studied elements were detected by flame atomic absorption spectrometry (FAAS). The impact of several analytical parameters, such as pH, sample volume and coprecipitant amount as well as centrifugation rate and time was investigated to recover the examined metal ions. The influence of matrix ions was also tested, and no interferences were observed. The recovery values of the analyte ions were calculated and found to be in the range of 95–101%. The detection limits, corresponding to three times the standard deviation of the blank (N=10), were found to be in the range of 0.2–1.2μgL⁻¹. The relative standard deviation (RSD) was calculated to evaluate the precision of the proposed method and was found to be ≤5.0%. The calculated preconcentration factor was 100. The proposed method was successfully applied to separate and preconcentrate trace amounts of ions in several water and food samples. To confirm the accuracy and validate the proposed method, certified reference materials were analyzed with satisfactory results.
Показать больше [+] Меньше [-]Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate Полный текст
2013
Tufekci, Mehmet | Bulut, Volkan Numan | Elvan, Hamide | Ozdes, Duygu | Soylak, Mustafa | Duran, Celal
A new, simple, and rapid separation and preconcentration procedure, for determination of Pb(II), Cd(II), Zn(II), and Co(II) ions in environmental real samples, has been developed. The method is based on the combination of coprecipitation of analyte ions by the aid of the Mo(VI)–diethyldithiocarbamate–(Mo(VI)-DDTC) precipitate and flame atomic absorption spectrometric determinations. The effects of experimental conditions like pH of the aqueous solution, amounts of DDTC and Mo(VI), standing time, centrifugation rate and time, sample volume, etc. and also the influences of some foreign ions were investigated in detail on the quantitative recoveries of the analyte ions. The preconcentration factors were found to be 150 for Pb(II), Zn(II) and Co(II), and 200 for Cd(II) ions. The detection limits were in the range of 0.1–2.2 μg L⁻¹ while the relative standard deviations were found to be lower than 5 % for the studied analyte ions. The accuracy of the method was checked by spiked/recovery tests and the analysis of certified reference material (CRM TMDW-500 Drinking Water). The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions.
Показать больше [+] Меньше [-]Separation and Preconcentration of Cd(II), Cu(II), Ni(II), and Pb(II) in Water and Food Samples Using Amberlite XAD-2 Functionalized with 3-(2-Nitrophenyl)-1H-1,2,4-triazole-5(4H)-thione and Determination by Inductively Coupled Plasma–Atomic Emission Spectrometry Полный текст
2011
Kumar, Bommana Naresh | Ramana, D. K Venkata | Harinath, Yapati | Seshaiah, Kalluru | Wang, M.C.
A separation and preconcentration procedure was developed for the determination of trace amounts of Cd(II), Cu(II), Ni(II), and Pb(II) in water and food samples using Amberlite XAD-2 fuctionalized with a new chelating ligand, 3-(2-nitrophenyl)-1H-1,2,4-triazole-5(4H)-thione (Amberlite XAD-2-NPTT). The chelating resin was characterized by Fourier transform infrared spectroscopy (FT-IR) and used as a solid sorbent for enrichment of analytes from samples. The sorbed elements were subsequently eluted with 10 mL of 1.0 M HNO3, and the eluates were analyzed by inductively coupled plasma–atomic emission spectrometry. The influences of the analytical parameters including pH, amount of adsorbent, eluent type and volume, flow rate of the sample solution, volume of the sample solution, and effect of matrix on the preconcentration of metal ions have been studied. The optimum pH for the sorption of four metal ions was about 6.0. The limits of detection were found to be 0.22, 0.18, 0.20, and 0.16 μg L-1 for Cd(II), Cu(II), Ni(II), and Pb(II), respectively, with a preconcentration factor 60. The proposed method was applied successfully for the determination of metal ions in water and food samples.
Показать больше [+] Меньше [-]