Уточнить поиск
Результаты 11-20 из 420
Challenge with Bovine viral diarrhea virus by exposure to persistently infected calves: protection by vaccination and negative results of antigen testing in nonvaccinated acutely infected calves Полный текст
2006
Fulton, R.W. | Johnson, B.J. | Briggs, R.E. | Ridpath, J.F. | Saliki, J.T. | Confer, A.W. | Burge, L.J. | Step, D.L. | Walker, D.A. | Payton, M.E.
Calves persistently infected (PI) with Bovine viral diarrhea virus (BVDV) represent an important source of infection for susceptible cattle. We evaluated vaccine efficacy using calves PI with noncytopathic BVDV2a for the challenge and compared tests to detect BVDV in acutely or transiently infected calves versus PI calves. Vaccination with 2 doses of modified live virus vaccine containing BVDV1a and BVDV2a protected the calves exposed to the PI calves: neither viremia nor nasal shedding occurred. An immunohistochemistry test on formalin-fixed ear notches and an antigen-capture enzyme-linked immunosorbent assay on fresh notches in phosphate-buffered saline did not detect BVDV antigen in any of the acutely or transiently infected calves, whereas both tests had positive results in all the PI calves.
Показать больше [+] Меньше [-]Histomorphologic evaluation of extracorporeal shock wave therapy of the fourth metatarsal bone and the origin of the suspensory ligament in horses without lameness Полный текст
2006
Bischofberger, A.S. | Ringer, S.K. | Geyer, H. | Imboden, I. | Ueltschi, G. | Lischer, C.J.
Objective-To determine via histologic examination and scintigraphy the effect of focused extracorporeal shock wave therapy (ESWT) on normal bone and the bone-ligament interface in horses. Animals-6 horses without lameness. Procedure-Origins of the suspensory ligament at the metacarpus (35-mm probe depth) and fourth metatarsal bone (5-mm probe depth) were treated twice (days 0 and 16) with 2,000 shocks (energy flux density, 0.15 mJ/mm2). One forelimb and 1 hind limb were randomly treated, and the contralateral limbs served as nontreated controls. Bone scans were performed on days -1 (before ESWT), 3, 16, and 19. Histomorphologic studies of control and treated tissues were performed on day 30. Results-ESWT significantly increased the number of osteoblasts but caused no damage to associated soft tissue structures and did not induce cortical microfractures. A significant correlation between osteoblast numbers and radiopharmaceutical uptake was noticed on lateral views of the hind limb on days 3 and 16 and on caudal views of the forelimb on day 3. Conclusions and Clinical Relevance-Results suggested that ESWT has the potential to increase osteoblast numbers in horses. The correlation between increased osteoblast numbers and radiopharmaceutical uptake 3 days and 16 days after the first ESWT suggested that stimulation of osteogenesis occurred soon after ESWT. No damage to bone or the bone-ligament interface should occur at the settings used in this study, and ESWT can therefore be administered safely in horses.
Показать больше [+] Меньше [-]Evaluation of administration of isoflurane at approximately the minimum alveolar concentration on depression of a nociceptive withdrawal reflex evoked by transcutaneous electrical stimulation in ponies Полный текст
2006
Spadavecchia, C. | Levionnois, O. | Kronen, P.W. | Leandri, M. | Spadavecchia, L. | Schatzmann, U.
Objective-To investigate effects of isoflurane at approximately the minimum alveolar concentration (MAC) on the nociceptive withdrawal reflex (NWR) of the forelimb of ponies as a method for quantifying anesthetic potency. Animals-7 healthy adult Shetland ponies. Procedure-Individual MAC (iMAC) for isoflurane was determined for each pony. Then, effects of isoflurane administered at 0.85, 0.95, and 1.05 iMAC on the NWR were assessed. At each concentration, the NWR threshold was defined electromyographically for the common digital extensor and deltoid muscles by stimulating the digital nerve; additional electrical stimulations (3, 5, 10, 20, 30, and 40 mA) were delivered, and the evoked activity was recorded and analyzed. After the end of anesthesia, the NWR threshold was assessed in standing ponies. Results-Mean +/- SD MAC of isoflurane was 1.0 +/- 0.2%. The NWR thresholds for both muscles increased significantly in a concentration-dependent manner during anesthesia, whereas they decreased in awake ponies. Significantly higher thresholds were found for the deltoid muscle, compared with thresholds for the common digital extensor muscle, in anesthetized ponies. At each iMAC tested, amplitudes of the reflex responses from both muscles increased as stimulus intensities increased from 3 to 40 mA. A concentration-dependent depression of evoked reflexes with reduction in slopes of the stimulus-response functions was detected. Conclusions and Clinical Relevance-Anesthetic-induced changes in sensory-motor processing in ponies anesthetized with isoflurane at concentrations of approximately 1.0 MAC can be detected by assessment of NWR. This method will permit comparison of effects of inhaled anesthetics or anesthetic combinations on spinal processing in equids.
Показать больше [+] Меньше [-]Prevalence of exposure to Salmonella spp in finishing swine marketed in Iowa Полный текст
2006
O'Connor, A.M. | McKean, J.D. | Beary, J.H. | Brockus, S.L.
Objective-To describe the prevalence of antibodies against Salmonella spp in swine marketed in Iowa. Animals-Swine marketed by 1,044 low-volume producers and 45 high-volume producers. Procedure-Samples of diaphragm muscle collected from swine carcasses were tested by an indirect ELISA based on lipopolysaccharides from Salmonella spp, in particular Salmonella serovar Typhimurium. Prevalence of positive results for antibodies against Salmonella spp for carcasses, lots, and swine for each producer was determined. Producer-level seroprevalence was used to classify swine from producers as having negligible, low, moderate, or widespread evidence of previous or historical exposure to Salmonella spp. Results-From low-volume producers, 23,609 of 25,478 (92.7%; 95% confidence interval CI, 92.4% to 92.9%) samples had negative results, and 1,863 (7.3%; 95% CI, 7.05% to 7.56%) had antibodies against Salmonella spp. Of the 6,299 lots of swine tested, 1,191 (18.9%) contained at least 1 sample with positive results. From high-volume producers, 203 of 2,486 (8.1 %; 95% CI, 6.8% to 9.3%) samples had antibodies against Salmonella spp, and 124 of 629 lots had at least 1 sample with positive results for antibodies against Salmonella spp. Conclusions and Clinical Relevance-Less than 10% of pigs marketed in Iowa are apparently exposed to Salmonella spp. Most swine marketed by low-volume producers had negligible or little evidence of exposure to Salmonella spp, whereas a higher percentage of swine marketed by high-volume producers had positive results when tested to detect antibodies against Salmonella spp.
Показать больше [+] Меньше [-]Evaluation of delayed-image bone scintigraphy to assess bone formation after distraction osteogenesis in dogs Полный текст
2006
Theyse, L.F. | Hazewinkel, H.A. | Terlou, M. | Pollak, Y.W. | Voorhout, G.
Objective-To quantitatively assess distraction-induced bone formation in a crural lengthening model in dogs by use of delayed-image bone scintigraphy. Animals-12 mature Labrador Retrievers. Procedure-Dogs were randomly allocated to 1 of 3 groups. A circular external skeletal fixation system was mounted on the right crus of each dog. Osteotomy of the distal portion of the tibia and fibula was performed in groups 1 and 2 and was followed by a lengthening procedure of 10 mm in the first group only. The third group served as sham-operated controls. Delayed-image bone scintigraphy with technetium-99m hydroxy methylene diphosphonate was performed 2, 4, and 6 weeks after surgery. Delayed-image-to-region-of-interest, delayed-image-to-crural, and delayed-image-to-femoral scintigraphic activity ratios were calculated. New bone formation was quantified by use of densitometric image analysis, and values for the scintigraphic ratios were compared. Results-In the distraction and osteotomy groups, delayed-image-to-region-of-interest and delayed-image-to-crural ratios increased significantly. Although densitometric image analysis revealed increased bone formation after distraction, the region-of-interest ratios and crural ratios were similar in both groups. All dogs had increased delayed-image-to-femoral ratios. Conclusions and Clinical Relevance-Delayed-image bone scintigraphy ratios were not effective at differentiating between the amounts of distraction-induced bone and osteotomy-induced bone. Metabolic bone activity in the adjacent femur was increased as a consequence of circular external skeletal fixator placement. Delayed-image bone scintigraphy was not adequately sensitive to quantitatively monitor bone formation but may be useful as an early predictor of bone healing.
Показать больше [+] Меньше [-]Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates Полный текст
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Показать больше [+] Меньше [-]Pharmacokinetics of intravenously administered caffeine in healthy alpacas (Lama pacos) and llamas (Lama glama) Полный текст
2006
Lakritz, J. | Middleton, J.R. | Anderson, D.E. | Linden, D.R. | Sams, R.A. | Tessman, R.K. | Tyler, J.W.
Objective-To determine the pharmacokinetic disposition of IV administered caffeine in healthy Lama spp camelids. Animals-4 adult male alpacas and 4 adult female llamas. Procedures-Caffeine (3 mg/kg) was administered as an IV bolus. Plasma caffeine concentrations were determined by use of high-performance liquid chromatography in 6 animals and by use of liquid chromatography-mass spectrometry in 2 llamas. Results-Median elimination half-life was 11 hours (range, 9.3 to 29.8 hours) in alpacas and 16 hours (range, 5.4 to 17 hours) in llamas. The volume of distribution at steady state was 0.60 L/kg (range, 0.45 to 0.93 L/kg) in alpacas and 0.75 L/kg (range, 0.68 to 1.15 L/kg) in llamas. Total plasma clearance was 44 mL/h/kg (range, 24 to 56 mL/h/kg) in alpacas and 42 mL/h/kg (range, 30 to 109 mL/h/kg) in llamas. Conclusions and Clinical Relevance-High-performance liquid chromatography and liquid chromatography-mass spectrometry were suitable methods for determination of plasma caffeine concentrations in alpacas and llamas. Plasma caffeine concentration-time curves were best described by a 2-compartment model. Elimination half-lives, plasma clearance, volume of distribution at steady state, and mean residence time were not significantly different between alpacas and llamas. Intravenous administration of caffeine at a dose of 3 mg/kg did not induce clinical signs of excitement.
Показать больше [+] Меньше [-]Detection of autoantibodies against thyroid peroxidase in serum samples of hypothyroid dogs Полный текст
2006
Skopek, E. | Patzl, M. | Nachreiner, R.F.
Objective-To establish a sensitive test for the detection of autoantibodies against thyroid peroxidase (TPO) in canine serum samples. Sample Population-365 serum samples from dogs with hypothyroidism as determined on the basis of serum concentrations of total and free triiodothyronine (T3), total and free thyroxine (T4), and thyroid-stimulating hormone, of which 195 (53%) had positive results for at least 1 of 3 thyroid autoantibodies (against thyroglobulin Tg, T4, or T3) and serum samples from 28 healthy dogs (control samples). Procedure-TPO was purified from canine thyroid glands by extraction with detergents, ultracentrifugation, and precipitation with ammonium sulfate. Screening for anti-TPO autoantibodies in canine sera was performed by use of an immunoblot assay. Thyroid extract containing TPO was separated electrophoretically, blotted, and probed with canine sera. Alkaline phosphatase-conjugated rabbit anti-dog IgG was used for detection of bound antibodies. Results-TPO bands were observed at 110, 100, and 40 kd. Anti-TPO autoantibodies against the 40-kd fragment were detected in 33 (17%) sera of dogs with positive results for anti-Tg, anti-T4, or anti-T3 autoantibodies but not in sera of hypothyroid dogs without these autoantibodies or in sera of healthy dogs. Conclusions and Clinical Relevance-The immunoblot assay was a sensitive and specific method for the detection of autoantibodies because it also provided information about the antigen. Anti-TPO autoantibodies were clearly detected in a fraction of hypothyroid dogs. The value of anti-TPO autoantibodies for use in early diagnosis of animals with thyroid gland diseases should be evaluated in additional studies.
Показать больше [+] Меньше [-]Use of intra-articular administration of ethyl alcohol for arthrodesis of the tarsometatarsal joint in healthy horses Полный текст
2006
Shoemaker, R.W. | Allen, Alan A. | Richardson, C.E. | Wilson, D.G.
Objective-To evaluate the efficacy and safety of intra-articular administration of ethyl alcohol for arthrodesis of tarsometatarsal joints in horses. Animals-8 healthy female horses without lameness or radiographic evidence of tarsal joint osteoarthritis. Procedure-In each horse, 1 tarsometatarsal joint was treated with 4 mL of 70% ethyl alcohol and the opposite joint was treated with 4 mL of 95% ethyl alcohol. Lameness examinations were performed daily for 2 weeks, followed by monthly evaluations for the duration of the 12-month study. Radiographic evaluations of both tarsi were performed 1 month after injection and every 3 months thereafter. Gross and histologic examinations of the tarsi were undertaken at completion of the study. Results-Horses had minimal to no lameness associated with the treatments. Radiography revealed that 8 of 16 joints were fused by 4 months after treatment, with significantly more joints fused in the 70% ethyl alcohol group. Fifteen of 16 joints were considered fused at postmortem examination at 12 months. Gross and histologic examinations revealed foci of dense mature osteonal bone spanning the joint spaces. Bony fusion appeared to be concentrated on the dorsolateral, centrolateral, and plantarolateral aspects of the joints. Significant differences were not detected between treatment groups for lameness or pathologic findings. Conclusions and Clinical Relevance-Administration of ethyl alcohol into the tarsometatarsal joint of healthy horses appeared to facilitate arthrodesis of the joint in a pain-free manner. Results warrant further investigation into the potential use of ethyl alcohol in horses clinically affected with osteoarthritis of the tarsometatarsal and distal intertarsal joints.
Показать больше [+] Меньше [-]Comparison of B-mode and Doppler ultrasonographic findings with histologic features of benign and malignant mammary tumors in dogs Полный текст
2006
Nyman, H.T. | Nielsen, O.L. | McEvoy, F.J. | Lee, M.H. | Martinussen, T. | Hellmen, E. | Kristensen, A.T.
Objective-To compare and correlate B-mode and color Doppler ultrasonographic characteristics with the histologic findings of benign and malignant mammary tumors in dogs. Study Population-49 mammary tumors in 26 dogs. Procedures-Before excision, tumors were evaluated via B-mode and color Doppler ultrasonography to assess size, echogenicity, echopattern, acoustic transmission, invasiveness, and vascularity. Paraffin-embedded microsections of the tumors were stained with H&E and examined for presence of necrosis, cysts, cartilage, bone, mineralization, invasion of surrounding tissue, and tissue heterogeneity. To assess vascularity, the number and distribution of vessels that were stained by the Verhoeff van Gieson technique were recorded. Results-Tumor echogenicity and echopattern on ultrasonographic images correlated with tissue heterogeneity detected histologically. Acoustic enhancement was correlated with the presence of necrotic or cystic areas. Tumor invasion into surrounding tissues as determined ultrasonographically did not correlate with the histologic findings. There was a significant correlation between the number of detected vessels and distribution of flow within the tumors determined via ultrasonographic and histologic examinations. Conclusions and Clinical Relevance-In canine mammary tumors, ultrasonographic characteristics appear to be correlated with histopathologic changes. Data suggest that ultrasonography may have an important role in the evaluation of mammary tumors in dogs, particularly in the evaluation of tissue composition and tumor vascularity.
Показать больше [+] Меньше [-]